ABAP Keyword Documentation → ABAP - Reference → program editing → Dynamic Program Editing → Source Code
INSERT REPORT
Other versions: 7.31 | 7.40 | 7.54
Syntax
INSERT REPORT prog FROM itab
[MAXIMUM WIDTH INTO wid]
{ [KEEPING DIRECTORY ENTRY]
| { [PROGRAM TYPE pt]
[FIXED-POINT ARITHMETIC fp]
[UNICODE ENABLING uc] }
| [DIRECTORY ENTRY dir] }.
Extras
1. ... MAXIMUM WIDTH INTO wid
2. ... KEEPING DIRECTORY ENTRY
3. ... PROGRAM TYPE pt
4. ... FIXED-POINT ARITHMETIC fp
5. ... UNICODE ENABLING uc
6. ... DIRECTORY ENTRY dir
Effect
This statement places the contents of itab
as source code into the ABAP program specified in prog
in the
repository. If a program
with the specified name already exists, its source code is overwritten. Otherwise a new program with
the name specified in prog
and the source code from itab
is created in the Repository.
The additions for specifying the program attributes create the program attributes in the system table TRDIR.
If none of the additions are specified, the following default values are set when a new program is created:
- The original language is set to the system language stored in the profile parameter zcsa/system_language.
- The creation date and the date of last change, along with the corresponding time, are set to the current values.
- The program author last changed by attributes are set to the current user.
- The program status is set to active. The program is compiled when it is first executed.
- The program type is set to executable program.
- The application is set to the value of the current program.
- No logical database is connected with the program.
- Fixed point arithmetic is activated.
-
The setting for the Unicode check is adopted from the current program.
If none of the additions are specified, an existing programs attributes remain intact if it is overwritten, but with the following exceptions:
- The date and time of the last change are set to the current value.
- The last changed by attribute is set to the current user.
- The version number is increased by one.
-
The setting for the Unicode check is activated if the current program is a
Unicode program and a
non-Unicode program
is overwritten. The setting remains active if the current program is a non-Unicode program and a Unicode program is overwritten.
For itab
, only a standard table without
secondary table keys
is permitted. The row type of itab
must be character-like. A source code
line in itab
can contain a maximum of 255 characters. prog
must be a character-like flat data object, which can contain no more than 30 characters, and the content of which is not case-sensitive.
System Fields
sy-subrc | Meaning |
---|---|
0 | The program specified in prog was successfully created or overwritten. |
4 | An error occurred when creating or overwriting the program specified in prog . |
Notes
-
The
INSERT REPORT
statement must be used with extreme caution, because it can completely overwrite existing programs without warning. You can prevent any inadvertent overwriting by checking whether the specified name already exists in the NAME column of the system table TRDIR. -
If you use
INSERT REPORT
to create a new program, this program is not assigned to a package, so that it is not connected to the correction or transport systems. You must either assign the program to a package in ABAP Workbench or it is only suitable for temporary tasks in the current system. -
It is vital that you have a precise working knowledge of the programs' structures and names if you want to use the statement
INSERT REPORT
for programs organized in a framework program and with include programs when they were created in ABAP Workbench. - The program name that is created should comply with the naming conventions of ABAP Workbench if it is to be processed using the Workbench's tools.
-
INSERT REPORT
shoud be used in application programs in exceptional cases only. ABAP provides many other means of dynamic programming, which generally make creating source texts dynamically unnecessary (see the list in dynamic program processing).
Addition 1
... MAXIMUM WIDTH INTO wid
Effect
If you use the MAXIMUM WIDTH
addition, the number of characters of the longest
source code line in itab
is assigned to the variable wid
, which must be of data type i
.
Addition 2
... KEEPING DIRECTORY ENTRY
Effect
This addition is only effective when a program is overwritten. The statement behaves as if no additions are specified (see above), with the exception that the setting for the Unicode checkremains intact in the overwritten program.
Note
With this setting, the source code of non-Unicode programs can be overwritten from Unicode programs without the Unicode check being implicitly activated.
Addition 3
... PROGRAM TYPE pt
Effect
This addition specifies the attribute
program type for the created or overwritten program in accordance with the setting in pt
,
which must be a data object of the data type c
and length 1 containing the ID of a program type. The following table shows the (case-sensitive) IDs of all program types.
ID | Program Type |
---|---|
1 | Executable program |
F | Function group or function pool |
I | Include program |
J | Interface pool |
K | Class pool |
M | Module pool |
S | Subroutine pool |
T | Type group or type pool |
Addition 4
... FIXED-POINT ARITHMETIC fp
Effect
This addition specifies the attribute
fixed point arithmetic for the created or overwritten program in accordance with the content of
fp
, which must be a data object of the data type c
and length 1 that has the value "X" or " ". The value "X" sets the fixed point arithmetic attribute, while the value " " deactivates it.
Addition 5
... UNICODE ENABLING uc
Effect
This addition specifies the setting of the
Unicode check for the created or overwritten program in accordance with the content of uc
,
which must be a data object of the data type c
and length 1 that has the value "X" or " ". The value "X" activates the Unicode check while the value " " deactivates it.
Note
With this addition, the source code of non-Unicode programs can be overwritten from Unicode programs without the Unicode check being implicitly activated. You can also create Unicode programs from non-Unicode programs.
Addition 6
... DIRECTORY ENTRY dir
Effect
This addition specifies the
program attributes for the created or overwritten program in accordance with the content of
dir fest, which must be structure of the data type TRDIR from ABAP
Dictionary. In the components of this structure, you can specify the required program attributes. Invalid
contents result in invalid program attributes. All program attributes are obtained from dir
,
with the exception of the creation and change dates, and the corresponding times, program authors or
last changed by attributes, and the version numbers. The latter are set to the same values as if no specification had been made.
Note
When using the DIRECTORY ENTRY
addition, it is strongly recommended that
you only set the contents of dir
by reading the attributes of an existing program from the database table TRDIR.
Example
Partial conversion of a program to Unicode.
A non-Unicode program is imported and, by means of an example, the DESCRIBE FIELD
statement is converted to the syntax for
Unicode systems. The
source code of the program is then overwritten with the modified source code and the Unicode check is activated in the program attributes.
DATA: itab TYPE TABLE OF string,
prog TYPE sy-repid,
uc TYPE trdir-uccheck.
FIELD-SYMBOLS <line> TYPE string.
prog = ...
SELECT SINGLE uccheck
FROM trdir
INTO (uc)
WHERE name = prog AND
uccheck = ' '.
IF sy-subrc = 0.
READ REPORT prog INTO itab.
LOOP AT itab ASSIGNING <line>.
TRANSLATE <line> TO UPPER CASE.
IF <line> CS 'DESCRIBE FIELD' AND
<line> CS 'LENGTH' AND
<line> NS 'MODE'.
REPLACE '.' IN <line> WITH ' IN CHARACTER MODE.'.
ENDIF.
...
ENDLOOP.
SYNTAX-CHECK FOR itab ...
IF sy-subrc = 0.
INSERT REPORT prog FROM itab UNICODE ENABLING 'X'.
ENDIF.
ENDIF.
Exceptions
Catchable Exceptions
CX_SY_WRITE_SRC_LINE_TOO_LONG
-
Cause: A line in the source code contains more than 255 characters.
Runtime Error:INSERT_REPORT_LINE_TOO_LONG
Non-Catchable Exceptions
-
Cause: The program name
prog
is reserved internally; it begins with'%_T'
.
Runtime Error:INSERT_PROGRAM_INTERNAL_NAME
-
Cause: The program name
prog
begins with a blank, which is not permitted.
Runtime Error:INSERT_PROGRAM_NAME_BLANK
-
Cause: The program name
prog
is too long; it can be no more than 40 characters long.
Runtime Error:INSERT_PROGRAM_NAME_TOO_LONG
-
Cause: Suffix 2 in the program name
prog
is invalid or does not correspond to the specificationapptype
.
Runtime Error:INSERT_REPORT_BAD_APPENDAGE
-
Cause: The specification
apptype
is invalid. Valid values are defined in the type group SREXT.
Runtime Error:INSERT_REPORT_BAD_APPTYPE
-
Cause: Suffix 1 in the program name
prog
is invalid or does not correspond to the specificationexttype
.
Runtime Error:INSERT_REPORT_BAD_EXTENSION
-
Cause: The specification
exttype
is invalid. Valid values are defined in the type group SREXT.
Runtime Error:INSERT_REPORT_BAD_EXTTYPE
-
Cause: The value of the field
uc
is not'X'
or' '
.
Runtime Error:INSERT_REPORT_ILLEGAL_FLAG
-
Cause: The value of the field
pt
is not '1','I'
,'S'
,'M'
,'F'
,'J'
, or'K'
.
Runtime Error:INSERT_REPORT_ILLEGAL_PROGTYPE
-
Cause: The program name
prog
is longer than 30 characters and the program does not yet exist in the library. Without the... APPENDAGE TYPE apptype
addition, the program cannot be inserted.
Runtime Error:INSERT_REPORT_NO_APPTYPE
-
Cause: The program name
prog
is longer than 30 characters and the program does not yet exist in the library. Without the... EXTENSION TYPE exttype
addition, the program cannot be inserted.
Runtime Error:INSERT_REPORT_NO_EXTTYPE