ABAP Keyword Documentation → ABAP - Reference → Processing Internal Data → Assignments → Assigning References → Setting Field Symbols → ASSIGN
ASSIGN - range_spec
Other versions: 7.31 | 7.40 | 7.54
Syntax
... { }
| {RANGE range}.
Alternatives
Effect
The range_spec
specification defines the area limits within which a memory
area can be assigned to the field symbol. Either nothing can be specified here or the addition RANGE
.
At the same time, the statement ASSIGN
assigns these area limits to the field
symbol <fs>
. If the field symbol <fs>
is
itself used in a subsequent ASSIGN
statement to specify a memory area
mem_area
, the assigned memory areas are used for determining the area limits of the field symbol that is being assigned.
Note
The area limits assigned to a field symbol using range_spec
only apply to
the following ASSIGN
statements. In other statements, with the exception of ADD UNTIL
, the
general rules apply.
Alternative 1
... { }
Effect
If no value is specified for range_spec
, the area limits are defined as follows:
-
If an elementary data object was specified for
dobj
inmem_area
, the memory area of this data object determines the area limits. -
If a field symbol was specified for
dobj
inmem_area
, and this field symbol has an elementary data object assigned to it, the field symbol<fs>
of the current statement takes on the area limits assigned to this field symbol. -
If a structure or a field symbol was specified for
dobj
inmem_area
, and one of these points to a structure, the system checks whether the structure has a character-like initial part (up to the first alignment gap). This then determines the area limits.
If these area limits are exceeded, no memory area is assigned for the static variant of mem_area
after the ASSIGN
statement. Also, the
predicate expression
<fs> IS ASSIGNED
is incorrect, while sy-subrc
is set to 4 in the dynamic variant.
Note
If no value is specified for range_spec
, the area limits in
obsolete non-Unicode programs are defined as follows:
-
If the name of a data object is specified directly in the when the memory area
mem_area
is specified statically, the area limits are determined by the data area of the ABAP program. -
If the name of a data object is specified dynamically for the specification of the memory area
mem_area
, the area limits are determined by the dynamically specified data object.
If these area limits are exceeded, an unhandleable exception is raised. If the area limits are the same as the data area of the ABAP program, this data area must also contain the administration information for
deep data objects because otherwise
errors could occur if these are exceeded unintentionally. Since cross-field offsets/lengths can also
be specified in structures to edit repeating groups, the additions RANGE
and INCREMENT
were introduced.
Example
In the first ASSIGN
statement, the area limits of the data object text
are assigned to <fs1>
. In the second ASSIGN
statement, <fs2>
takes on these limits. From the sixth loop pass, an attempt
is made to assign a larger memory area to <fs2>
. In Unicode programs,
therefore, the logical expression after IF
is no longer true, whereas in non-Unicode programs, the larger memory area is assigned.
DATA text TYPE c LENGTH 8 VALUE '12345678'.
FIELD-SYMBOLS: <fs1> TYPE ANY,
<fs2> TYPE ANY.
ASSIGN text+3(3) TO <fs1>.
DO 8 TIMES.
ASSIGN <fs1>(sy-index) TO <fs2>.
IF <fs2> IS ASSIGNED.
cl_demo_output=>write_text( |{ <fs2> }| ).
ENDIF.
ENDDO.
cl_demo_output=>display( ).
Alternative 2
... RANGE range
Effect
If the RANGE
addition is specified in range_spec
, the area limits are defined by the
data area of a range
data object. range
expects a data object of any data type. It must cover
the area limits in Unicode programs when the RANGE
addition is not specified
(see above). If it is established at runtime that range
does not cover these area limits, an unhandleable exception is raised.
When the RANGE
addition is used, only subareas of the range
data object can be assigned to the field symbol. If these area limits are exceeded, no memory area is
assigned for the static variant of mem_area
after the ASSIGN
statement. Also, the
predicate expression
<fs> IS ASSIGNED
is incorrect, while sy-subrc
is set to 4 in the dynamic variant.
The addition RANGE
cannot be used with the addition CASTING TYPE HANDLE
or for assigning
table expressions.
Notes
-
A
RANGE
addition does not remove the type-specific rules for substring accesses. To enable substring access beyond the field limits of a specified data objectdobj
, substring access must be possible in principle. In particular, substring access is never possible beyond the limits of a structure in a Unicode program, since the character-like initial part is not accessed in this case. -
If a structure is specified for
range
that contains dynamic data objects, they only contribute the internal reference to the data area of the structure. The actual data area of the dynamic data objects is outsourced and is of no significance forRANGE
. This also applies to substructures that are declared as boxed components.
Example
The struc
structure is constructed from ten components col1_1
,
col2_1
, ..., col1_5
, col2_5
.
The ASSIGN
statement assigns the memory area of two neighboring components
to the structure-typed field symbol <sub>
, one after the other. Here the
memory area is determined by the common name of the first two components comp1
in the structure struc
and the specification of INCREMENT
.
Without the RANGE
addition, the WHILE
loop would
only execute once in Unicode programs since it would only be possible to access the memory area of
struc-comp1. The RANGE
addition causes the loop to be passed five times. The components of the field symbol can be accessed after the assignment.
TYPES: BEGIN OF sub_struc,
col1 TYPE c LENGTH 10,
col2 TYPE c LENGTH 10,
END OF sub_struc.
DATA BEGIN OF struc.
INCLUDE TYPE: sub_struc AS comp1 RENAMING WITH SUFFIX _1,
sub_struc AS comp2 RENAMING WITH SUFFIX _2,
sub_struc AS comp3 RENAMING WITH SUFFIX _3,
sub_struc AS comp4 RENAMING WITH SUFFIX _4,
sub_struc AS comp5 RENAMING WITH SUFFIX _5.
DATA END OF struc.
FIELD-SYMBOLS <sub> TYPE sub_struc.
struc = VALUE #( col1_1 = 'col1_1' col2_1 = 'col2_1'
col1_2 = 'col1_2' col2_2 = 'col2_2'
col1_3 = 'col1_3' col2_3 = 'col2_3'
col1_4 = 'col1_4' col2_4 = 'col2_4'
col1_5 = 'col1_5' col2_5 = 'col2_5' ).
DATA inc TYPE i.
WHILE sy-subrc = 0.
inc = sy-index - 1.
ASSIGN struc-comp1 INCREMENT inc TO <sub> CASTING
RANGE struc.
IF sy-subrc = 0.
cl_demo_output=>write_data( <sub> ).
ENDIF.
ENDWHILE.
cl_demo_output=>display( ).