ABAP Keyword Documentation → ABAP - Reference → User Dialogs → Dynpros → ABAP Statements for Screens
SET PF-STATUS - Dynpro
Other versions: 7.31 | 7.40 | 7.54
Syntax
SET PF-STATUS status [OF PROGRAM prog] [EXCLUDING fcode].
Extras
1. ... OF PROGRAM prog
2. ... EXCLUDING fcode
Effect
In dynpro processing, this statement defines the
GUI status defined in status
for the subsequent
screen layouts. The components
of the set status are active in the user interface from the next time a screen layout is sent, and remain
active until the end of the program or until the next SET PF-STATUS
statement. The name of the current GUI status can be read from the system field sy-pfkey
.
status
expects a character-like data object that contains either the name of the GUI status of the
main program of the current
program group, or the
program specified in uppercase (or only blanks) in prog
. If the status is
not available, an empty status is displayed, in which no control elements are active except for the
predefined system functions. Of these functions, only the Enter key, to which an empty function code is assigned in this case, triggers the event
PAI. If the data object status
contains only blanks, the
standard list status is set and the additions have no effect.
Notes
- The GUI status of a dynpro must be set at the latest during the event PBO. If no GUI status is set for a dynpro, the empty status described above is used.
-
If the set GUI status contains dynamic function texts, the function texts are read from the assigned
global data objects of the program in which the GUI status is defined. If these do not exist, question
marks (?) are displayed. For dynamic function texts, an explicitly specified program
prog
is loaded into the current program group if it does not already exist in the internal session. This enables access to its global data objects. -
The statement
SET PF-STATUS
has a variant for the GUI status of lists. -
There is no guarantee that the statement
SET PF-STATUS
will work at PBO for the selection screen. This statement should no longer be used for selection screens. -
If a switch is assigned to an element of the GUI status in Menu Painter, this controls the activation of this element.
Addition 1
... OF PROGRAM prog
Effect
By default, a GUI status defined in the current
main program is used. The addition OF PROGRAM
can be used to set the
GUI status of the program specified in prog
. prog
expects a character-like data object that contains the name of the ABAP program in uppercase.
Addition 2
... EXCLUDING fcode
Effect
The addition EXCLUDING
can be used to deactivate functions of the set GUI
status. An inactive function cannot be selected in the user interface. fcode
expects either a character-like data object or an internal table with a
flat character-like row type.
The functions whose function codes are contained in the field or in the rows of the internal table are
deactivated. Only one function code can be specified for each row of the table. The codes are not case-sensitive.
Function codes specified in fcode
for which there is no function in the GUI status are ignored.
Example
Sets the GUI status STATUS_0100 of the main program in a PBO module, where the functions with the function codes "CHANGE" and "SAVE" are deactivated.
DATA fcode TYPE TABLE OF sy-ucomm.
...
MODULE status_0100 OUTPUT.
APPEND 'CHANGE' TO fcode.
APPEND 'SAVE' TO fcode.
SET PF-STATUS 'STATUS_0100' EXCLUDING fcode.
ENDMODULE.