ABAP Keyword Documentation → ABAP − Reference → Processing Internal Data → Internal Tables → Processing Statements for Internal Tables → LOOP AT itab → LOOP AT itab - Basic Form
AT - Group Level Processing
Other versions: 7.31 | 7.40 | 7.54
Syntax
LOOP AT itab
result [cond].
[AT FIRST.
...
ENDAT.]
[AT NEW comp1.
...
ENDAT.
[AT NEW comp2.
...
ENDAT.
[...]]]
[ ... ]
[[[...]
AT END OF comp2.
...
ENDAT.]
AT END OF comp1.
...
ENDAT.]
[AT LAST.
...
ENDAT.]
ENDLOOP.
Extras
1. ... FIRST
2. ... {NEW}|{END OF} compi
3. ... LAST
Effect
The statement block of a LOOP
without the addition GROUP BY can contain control structures for
group level processing.
The corresponding control statement is AT. The statements AT and ENDAT define statement blocks that are executed at
group breaks, that is in the transition of a
group level to another
group level. The additions of the statements AT define the criteria for a
group break and hence the group levels. Group breaks between group levels are a result of the row structure
and the processing order in which the LOOP reads the rows of the internal
table. Within the statement blocks, the statement SUM can be specified to total the numeric components of a group level.
Apart from the special variants AT FIRST and AT LAST,
group levels are defined using the variants AT NEW AT
END OF and the sequence of rows (in accordance with the processing order of the loop) in the
internal table. These are the rows that have the same content in a group key defined in their initial
parts. Here, all rows of the internal table are respected without evaluating any restricting conditions cond.
It is possible, from a syntax point of view, to arrange AT control structures
in any order and to nest them, however effective group level processing is usually only achieved by
the arrangement above. Here, the control structures are specified in accordance with the arrangement of the components in the group key and are not nested.
The statement blocks within the AT-ENDAT control
structures are listed if an appropriate group break is made in the current table line. Statements in
the LOOP-ENDLOOP control structure that are not
executed within an AT-ENDAT control structure
are executed in each pass of the loop. If a table row with a group break is not read due to a restricting
condition cond, the statement block in question is not executed.
The following rules must be followed for effective group level processing:
-
A table key specified in
LOOPin cond must be chosen so that it produces the required processing order of the imported rows. -
No restricting condition
condshould be specified. If a condition like this is specified, it should select consecutive row groups (including the first row in the group) where the group break takes place. -
The internal table cannot be modified within the
LOOPloop. -
A work area
waspecified in theLOOPstatement after the additionINTOmust be compatible with the row type of the table. -
A field symbol
<fs>specified in the statementLOOPafter the additionASSIGNINGmust be typed with the row type of the table. -
The content of a work area
waspecified in the statementLOOPafter the additionINTOcannot be modified.
If the addition INTO wa
is used in the statement LOOP,
the content of wa is overwritten (depending on the respective group level)
when the AT-ENDAT control structure is entered,
and is reset to the content of the current row when the control structure is exited. When the additions
ASSIGNING and
REFERENCE INTO are used, the referenced table rows are not modified when entering and exiting the AT-ENDAT control structure.
Notes
-
The most common case is when the internal table is sorted exactly by the order of the components of
its row type, by the first component first, then the second component, and so on. In this case, group
level processing can also be expressed using a grouping with the addition
GROUP BY. - If possible, the use of the addition GROUP BY is recommended, since the grouping is not determined by the structure of the rows and the processing order in this case.
-
Group level processing with the statement
ATis not possible inLOOPs across row groups with the addition GROUP BY, including member loops usingLOOP AT GROUP. -
The group level processing described here can produce unexpected results when a restricting condition
condis used, which means that extended syntax check messages can occur.
Executable Examples
Addition 1
... FIRST
Effect
The group level is defined by the first row of the internal table. The group break takes place when
this row is read. In the group level AT FIRST, the current group key does not contain any components.
If the addition INTO wa
is used in the statement LOOP,
all character-like components of the work area wa are filled with "*" when
the control structure AT FIRST is entered and all other components are set
to their initial value. In the case of an elementary row type, this applies to the whole work area.
When the AT-ENDAT control structure is exited, the content of the current table row is reassigned to the work area wa.
Note
If the first row of the internal table is not read due to a restricting condition
cond, the statement block of the control structure AT FIRST is not executed.
Example
Displays a header and the first row of an internal table at the group level AT FIRST.
DATA itab TYPE SORTED TABLE OF scarr
WITH UNIQUE KEY carrid.
SELECT *
FROM scarr
INTO TABLE itab.
DATA(out) = cl_demo_output=>new( ).
LOOP AT itab ASSIGNING FIELD-SYMBOL(<fs>).
AT FIRST.
out->next_section( 'First' ).
out->write( <fs> ).
ENDAT.
ENDLOOP.
out->display( ).
Addition 2
... {NEW}|{END OF} compi
Effect
Group levels are defined by the beginning or end of a group of rows with the same content in the component
compi (where i = 1,
2, and so on) and in the components on the left of compi.
The content of these components determines the group key. The group breaks take place when the content
of the component compi or another component on the left of compi changes.
The compi components can be specified as described in
Specification of Components, with the limitation that access to data objects using references is not possible here. The following is therefore not possible:
- Specifying data objects using data references
-
Specifying attributes of objects using object references
Otherwise, the specified components can have any data type. The relevant
comparison rules apply to the evaluation. In the case of an elementary row type, only table_line can be specified as the group key.
If the addition INTO wa
is used in the statement LOOP,
the content of wa is modified as follows when the AT-ENDAT control structure is entered:
- The components of the current group key remain unchanged.
- All components with a character-like flat data type on the right of the current control key are set to the character "*" in every place.
-
All the other components to the right of the current group key are set to their initial value.
In the case of an elementary row type, the whole work area corresponds to the current group key and
does not change. When the AT-ENDAT control structure
is exited, the content of the current table row is reassigned to the work area wa.
Notes
- Group levels defined in this way consist of the contiguous rows of the internal table that have the same content in an initial part.
-
If the first or last row of a row group is not read due to a restricting condition
cond, the statement block of the control structureAT NEWorAT END OFis not executed. -
An obsolete variant allows field symbols to also be specified, outside of classes
compi.
Example
Displays the carrid column as a header for the chained content of the associated flight numbers.
DATA itab TYPE SORTED TABLE OF spfli
WITH UNIQUE KEY carrid connid.
SELECT *
FROM spfli
INTO TABLE itab.
DATA connids TYPE string.
DATA(out) = cl_demo_output=>new( ).
LOOP AT itab ASSIGNING FIELD-SYMBOL(<fs>).
AT NEW carrid.
out->next_section( <fs>-carrid ).
ENDAT.
connids = connids && ` ` && <fs>-connid.
AT END OF carrid.
out->write( connids ).
CLEAR connids.
ENDAT.
ENDLOOP.
out->display( ).
Example
The first row of the first row group is not read due to the addition FROM
2, which means the associated statement block after AT NEW table_line is not executed. The program therefore produces a message from the extended program check.
DATA itab TYPE TABLE OF string WITH EMPTY KEY.
itab = VALUE #( ( `AA` ) ( `AA` ) ( `AA` )
( `BB` ) ( `BB` ) ( `BB` ) ).
DATA(out) = cl_demo_output=>new( ).
LOOP AT itab ASSIGNING FIELD-SYMBOL(<fs>) FROM 2.
AT NEW table_line.
out->write( <fs> ).
ENDAT.
ENDLOOP.
out->display( ).
Addition 3
... LAST
Effect
The group level is defined by the last row of the internal table. The group break takes place when this
row is read. In the group level AT LAST, the current group key does not contain any components.
If the addition INTO wa
is used in the statement LOOP,
all character-like components of the work area wa are filled with "*" when
the control structure AT LAST is entered and all other components are set
to their initial value. In the case of an elementary row type, this applies to the whole work area.
When the AT-ENDAT control structure is exited, the content of the current table row is reassigned to the work area wa.
Note
If the last row of the internal table is not read due to a restricting condition
cond, the statement block of the control structure AT LAST is not executed.
Example
Displays cumulated content during the processing of the last row.
DATA itab TYPE SORTED TABLE OF scarr
WITH UNIQUE KEY carrid.
SELECT *
FROM scarr
INTO TABLE itab.
DATA carrids TYPE string.
LOOP AT itab ASSIGNING FIELD-SYMBOL(<fs>).
carrids = carrids && ` ` && <fs>-carrid.
AT LAST.
cl_demo_output=>display( carrids ).
ENDAT.
ENDLOOP.
Exceptions
Non-Handleable Exceptions
-
Cause: Invalid substring access when the group break criterion is specified dynamically.
Runtime error:AT_BAD_PARTIAL_FIELD_ACCESS -
Cause: The group break criterion is specified dynamically using the field symbol and the field symbol does not point to the
LOOPoutput range.
Runtime error:AT_ITAB_FIELD_INVALID -
Cause: The group break criterion is specified dynamically using
(name)and thenamefield does not contain a valid substring name.
Runtime error:ITAB_ILLEGAL_COMPONENT -
Cause: Overflow of totals with
SUM.
Runtime error:SUM_OVERFLOW