Skip to content

ABAP Keyword Documentation →  ABAP - Reference →  Program structure →  Modularization Statements →  Procedures →  Function Modules →  FUNCTION 

Function Module Interface

The parameter interface of a function module is defined in Function Builder. It includes the definition of interface parameters and the specification of exceptions that can be triggered by a function module. Function Builder automatically generates comment lines below the FUNCTION statement in the source code of the function module. These represent the interface of the function module with the following syntax:

Other versions: 7.31 | 7.40 | 7.54

Syntax


... [IMPORTING parameters] 
    [EXPORTING parameters]
          [TABLES table_parameters]
    [CHANGING parameters]
    [{RAISING exc1|RESUMABLE(exc1) exc2|RESUMABLE(exc2) ...}
    |{EXCEPTIONS exc1 exc2 ...}]

The syntax and semantics of IMPORTING, EXPORTING, CHANGING, RAISING, and EXCEPTIONS mainly correspond to the definition of method interfaces with [CLASS-]METHODS. The additional option of defining table parameters using TABLES is obsolete.

Interface Parameters

The interface parameters are defined on the relevant tab pages in Function Builder.

  • IMPORTING parameters are input parameters. When the function module is called, a suitable actual parameter must be specified for every non-optional input parameter. The content of the actual parameter is passed to the input parameter when the call is made. The content of an input parameter for which 'pass by reference' is defined cannot be changed in the function module.
  • EXPORTING parameters are output parameters. When the function module is called, a suitable actual parameter can be specified for every output parameter. The content of an output parameter that is defined for 'pass by value' is passed to the actual parameter if the function module is completed without errors. An output parameter that is defined for pass by reference is not initialized when the function module is called.
  • CHANGING parameters are input and output parameters. When the function module is called, a suitable actual parameter must be specified for every non-optional input or output parameter. When the function module is called, the content of the actual parameter is passed to the input/output parameter, and when the function module is completed, the content of the input/output parameter is passed to the actual parameter.


Note

The formal parameters of a function module can be registered as global parameters in Function Builder, however this is obsolete.

Exceptions

The exceptions of a function module are defined on the Exceptions tab page in Function Builder. Here, exception classes can be selected to define whether class-based exceptions are declared or non-class-based exception are defined. Class-based exceptions are represented in the above syntax by RAISING, and non-class-based exceptions are represented by EXCEPTIONS.

  • The addition RAISING is used to declare class-based exceptions that can be propagated from the function module to the caller. Exceptions in the categories CX_STATIC_CHECK and CX_DYNAMIC_CHECK must be explicitly declared, otherwise a propagation can lead to an interface violation. A violation of the interface raises the handleable exception CX_SY_NO_HANDLER. Exceptions of the category CX_NO_CHECK are always declared implicitly and with the RESUMABLE addition. The declaration of exceptions of the category CX_STATIC_CHECK is checked statically in the syntax check. For exceptions of the category CX_DYNAMIC_CHECK, the check is not performed until runtime. In a function module in which class-based exceptions are declared with the RAISING addition, the statement CATCH SYSTEM-EXCEPTIONS cannot be used. Instead, the relevant handleable exceptions should be handled in a TRY control structure.

    The RESUMABLE addition declares an exception that can be propagated as a resumable exception. This addition has no relevance to a non-resumable exception. The addition does not have any effect on a non-resumable exception. If a resumable exception is propagated with RAISING without the addition RESUMABLE, it thus becomes non-resumable. If a superclass is declared as resumable, any subclasses must also be declared as resumable.
  • The addition EXCEPTIONS is used to define a list of non-class-based exceptions that can be triggered in the function module using the statements RAISE or MESSAGE RAISING. Exceptions defined in this way are (as with formal parameters) bound to the function module and cannot be propagated. If an exception of this type is raised in a function module, and no return value has been assigned to it with the homonymous addition EXCEPTIONS of the CALL FUNCTION statement when the call was made, this leads to a runtime error. In a function module in whose interface non class-based exceptions are defined, it is not possible to use the statement RAISE EXCEPTION to raise class-based exceptions.

The Resumable column in Function Builder can be selected to flag a class-based exception as a resumable exception. This places the RESUMABLE addition behind RAISING in the syntax above.


Note

For new developments, SAP recommends the use of class-based exceptions that are independent of the function module.

Continue

Properties of Interface Parameters